White Rodgers 50A65-5165 Trane Single Stage Integrated Furnace Control, 80V Ignitor

  • Control-80V Ignitor
  • 80 VAC Ignitor Output
  • 120 VAC Humidifier Output
  • 120 VAC Electronic Air Cleaner Output
  • 120 VAC 2-Speed PSC Circulator Output
  • Fuse Protection - 5 Amp
  • Furnace Status LED
  • Heat Fan OFF Delay (Dipswitch Selectable)
  • Y, W, R, G, C, TWIN Terminals



NEW-Direct Replacement Integrated Furnace Control For Trane Single Stage HSI Controls with 80V Ignitors. Replaces Trane CNT03076, CNT3076, CNT03798, CNT3798, CNT05164, CNT5164, CNT05165, CNT5165, D341213P01, D341396P01, D341396P03, D341396P04, D341396P05, White-Rodgers 50A65-474, 50A65-475, 50A65-476

The 50A65-5165 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. Signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame,
and system shut-off during normal operation. These controls incorporates system fault analysis for quick gas flow shut-off, coupled with automatic ignition retry upon sensing a fault correction.

  • Pre-Purge 0 seconds
  • Ignitor Warm-up 20 seconds
  • Trial for Ignition Period 5 seconds
  • Ignition Activation Period 2 seconds
  • Retries 2 times
  • Valve Sequence Period 15 seconds
  • Interpurge 60 seconds
  • Post-Purge 5 seconds
  • Lockout Time 300 seconds
  • Heat Delay-To-Fan-On 45 seconds
  • Heat Delay-To-Fan-Off* 60/100/140/180 seconds
  • Cool Delay-To-Fan-On 2 seconds
  • Cool Delay-To-Fan-Off* 0/80 seconds
  • Humidifier Yes
  • Electronic Air Cleaner Yes
  • Auto Reset Purge 15 seconds



*These times will vary depending on option switch
position. The control is factory-set at 80 sec. cool
delay-to-fan-off and 180 sec. heat delay-to-fan-off.

 