Sure Comfort S802V Downflow Gas Furnaces
Models with Input Rates from 75 to 125 kBTU [15 to 44 kW]
• 80% residential Gas Furnace CSA certified
• Two stages of operation to save energy and maintain optimal comfort level.
• Variable speed blower motor technology provides ultimate humidity control, quieter sound levels, and year round energy savings
• Diagnostics — 7 Segment LED all units
• Ignition System – DSI for reliability and longevity
• Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability.
• Low profile 34" cabinet ideal for space constrained installations
• Integrated Control board features dip switches for easy system set up
• Insulated blower compartment
• QR code for quick access to product information from your smartphone or tablet
• Compatible with single or two stage thermostats. For optimal performance a two stage thermostat is recommended.
STANDARD EQUIPMENT
Completely assembled and wired; 2 speed induced draft blower; high and low pressure switches; 2 stage redundant main gas control; blower compartment door safety switch; solid state time on/time off blower control; limit control; transformer; ECM blower motor. Furnaces are equipped with cooling/heating relay and transformer (50VA) ready for air conditioning applications. (Please note: a thermostat is not included as standard equipment.) Flame sensor diagnostics; fused-protection (secondary), 3rd speed option for continuous fan.
Model Features
80% residential Gas Furnace CSA certified
Two stages of operation to save energy and maintain optimal comfort level.
Variable speed blower motor technology provides ultimate humidity control, quieter sound levels, and year round energy savings
Enabled HVAC product
7 Segment LED all units
Direct Spark Ignition for reliability and longevity
Heat exchanger is removable for improved serviceability. Aluminized steel construction provides maximum corrosion resistance and thermal fatigue reliability.
Low profile 34" cabinet ideal for space constrained installations
Integrated Controls board features dip switches for easy system set up
Insulated blower compartment
QR code for quick access to product information from your smart phone or tablet
Compatible with single or two stage thermostats. For optimal performance a two stage thermostat is recommended.
Physical Data and Specifications—Downflow Models |
|||||
MODEL NUMBERS S802V (DF) SERIES |
S802VA075317Z*A |
S802VA075421Z*A |
S802VA100521Z*A |
S802VA125524Z*A |
|
100% High Input–BTU/Hr [kW] ➁ |
75,000 [22] |
75,000 [22] |
100,000 [29] |
125,000 [37] |
|
High Heating Capacity–BTU/Hr [kW] ➀ |
60,000 [18] |
60,000 [18] |
80,000 [23] |
100,000 [29] |
|
70% Low Input–BTU/Hr [kW] |
52,500 [15] |
52,500 [15] |
70,000 [20] |
87,500 [25] |
|
Low Heating Capacity–BTU/Hr [kW] |
42,000 [12] |
42,000 [12] |
56,000 [16] |
70,000 [20] |
|
Heating–Ext. Static Pressure [kPa] |
.12 [.029] |
.12 [.029] |
.15 [.037] |
.20 [.05] |
|
Blower (D x W) [mm] |
11 x 7 |
11 x 10 |
11 x 10 |
11 x 10 |
|
[279 x 178] |
[279 x 254] |
[279 x 254] |
[279 x 254] |
||
ECM Motor H.P. [W] |
1/2 [373] |
3/4 [559] |
1 [746] |
1 [746] |
|
Motor Full Load Amps. |
7.7 |
9.6 |
12.8 |
12.8 |
|
Unit Amps |
8.7 |
12 |
12 |
12 |
|
Maximum Overcurrent Protection |
15 |
15 |
15 |
15 |
|
Cooling CFM @ .5" [kPa] E.S.P. |
600-1200 |
1000-1600 |
1200-2000 |
1200-2000 |
|
(Nominal) [L/s] (Range) |
[283]-[566] |
[472]-[755] |
[566]-[944] |
[566]-[944] |
|
Max. E.S.P. (In. W.C.) [kPa] |
0.8 [0.2] |
0.8 [0.2] |
0.8 [0.2] |
0.8 [0.2] |
|
Temperature Rise |
High Fire |
30-60 [17-33] |
25-55 [14-31] |
30-60 [17-33] |
35-65 [19.4-36.0] |
Range °F [°C] |
Low Fire |
20-50 [11-28] |
20-50 [11-28] |
25-55 [14-31] |
30-60 [17-33] |
Max. Outlet Air Temp. °F [°C] |
165 [73.9] |
165 [73.9] |
165 [73.9] |
185 [85] |
|
Approx. Shipping Weight (Lbs.) [kg] |
115 [52] |
115 [52] |
120 [54] |
140 [63] |
|
AFUE ➀ |
80.00% |
80.00% |
80.00% |
80.00% |
|
Notes: All models are 115V, 60 Hz, 1 Ph. Gas connection size for all models is 1/2" [12 mm] N.P.T. |
|||||
➀ In accordance with D.O.E. test procedures. |
|||||
➁ See Conversion Kit Index Form for high altitude derate in U.S. applications. |
Dimensions and Clearance to Combustible Material (inches) [mm] |
||||||||||||
MODEL S802V- SERIES |
A |
B |
C |
D |
E |
REDUCED CLEARANCES (IN.) [mm] |
||||||
LEFT SIDE |
RIGHT SIDE |
BACK |
TOP |
FRONT |
VENT |
SHIP. WGTS. (LBS.) [kg] |
||||||
75317 |
171/2 [445] |
1611/32 [415] |
121/8 [308] |
➀ |
165/8 [422] |
0 |
3 ➁ |
0 |
1 [25] |
3 [76] |
6 [152] ➂ |
110 [49.9] |
75421 |
211/2 [533] |
1927/32 [504] |
137/8 [352] |
➀ |
201/8 [511] |
0 |
0 |
0 |
1 [25] |
3 [76] |
6 [152] ➂ |
115 [52.2] |
100 |
211/2 [533] |
1927/32 [504] |
137/8 [352] |
➀ |
201/8 [511] |
0 |
0 |
0 |
1 [25] |
3 [76] |
6 [152] ➂ |
120 [54.4] |
125 |
241/2 [622] |
2311/32 [593] |
155/8 [397] |
➀ |
235/8 [600] |
0 |
0 |
0 |
1 [25] |
3 [76] |
6 [152] ➂ |
140 [63.5] |
NOTES: ➀ May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter. |
||||||||||||
➁ May be 0" [0 mm] with type B vent. |
||||||||||||
➂ May be 1" [25 mm] with type B vent. |
||||||||||||
Furnaces must be vented in accordance with the National Fuel Gas Code, ANSI Z223.1 and/or Can/CGA-B149 Installation Codes and in accordance with local codes. |
Blower Performance Data—Downflow Models |
|||||||
MODEL NUMBER |
S802VA075317ZSA |
S802VA075421ZSA |
S802VA100521ZSA |
S802VA125524ZSA |
|||
SW15 = OFF |
SW16 = OFF |
1254 |
1305 |
1651 |
1998 |
||
HIGH |
SW15 = ON |
SW16 = OFF |
1054 |
1173 |
1398 |
1600 |
|
TARGET GAS |
HEATING CFM |
SW15 = OFF |
SW16 = ON |
DO NOT USE |
|||
HEATING |
SW15 = ON |
SW16 = ON |
953 |
1001 |
1251 |
1595 |
|
AIRFLOW |
SW13 = OFF |
SW14 = OFF |
980 |
1125 |
1300 |
1480 |
|
LOW |
SW13 = ON |
SW14 = OFF |
850 |
850 |
1075 |
1250 |
|
HEATING CFM |
SW13 = OFF |
SW14 = ON |
DO NOT USE |
||||
SW13 = ON |
SW14 = ON |
750 |
700 |
875 |
1100 |
||
SW4 = OFF |
SW5 = OFF |
1200 |
1600 |
2000 |
2000 |
||
HIGH |
SW4 = ON |
SW5 = OFF |
1000 |
1400 |
1600 |
1600 |
|
TARGET |
COOLING CFM |
SW4 = OFF |
SW5 = ON |
800 |
1200 |
1400 |
1400 |
COOLING/ |
SW4 = ON |
SW5 = ON |
600 |
1000 |
1200 |
1200 |
|
HEAT-PUMP |
SW4 = OFF |
SW5 = OFF |
900 |
1200 |
1500 |
1500 |
|
AIRFLOW |
LOW |
SW4 = ON |
SW5 = OFF |
750 |
1050 |
1200 |
1200 |
COOLING CFM |
SW4 = OFF |
SW5 = ON |
600 |
900 |
1050 |
1050 |
|
SW4 = ON |
SW5 = ON |
450 |
750 |
900 |
900 |