Honeywell model R8184G4074 cad cell safety relay. Low Voltage Screw Terminals. Line Voltage Leadwire Connections. Intermittent Ignition with 45 Second Safety timing. 120 volt 60 Hz. Use with C554 cad cell assembly (not included). Mounts directly On Burner with 4X4 Junction Box. 30 Second safety Timing. - Provides automatic, nonrecycling control of an intermittent ignition oil burner system.
- Solid state flame sensing circuit.
- External button to manually reset safety switch after lockout.
- Mounts on standard 4 x 4 in. junction box.
| Description | Protectorelay Oil Burner Control with 30 seconds lock out timing | | Ignition Type | Intermittent | | Timing, Safety Switch | 30 sec. | | Mounting Bracket | For mounting on a standard 4 in. X 4 in. junction box or direct mounting on burner housing. | | Electrical Rating; Contacts (full load) | 7.4 A @ 120 Vac; 3.7 a @ 240 Vac | | Electrical Rating; Contacts (locked rotor) | 44.4 A @ 120 Vac; 22.2 A @ 240 Vac | | Alarm Load Ratings (pilot duty) | 75 VA @ 120/240 Vac, 50-60 Hz; 25 VA @ 24V, 50-60 Hz | | Alarm Load Ratings (resistive) | 1.5 A @ 120/240V, 50-60Hz; 3 A @ 24 V, 50-60 Hz | | Dimensions (in.) | 4 3/8 in. high x 4 1/8 in. wide x 2 1/2 in. deep | | Dimensions (mm) | 111 mm high x 104 mm wide x 64 mm deep | | Temperature Range (F) | -40 F to +130 F | | Temperature Range (C) | -40 C to +54 C | | Approvals, Underwriters Laboratories Inc | UL Component Recognized; File no. MP268, Vol. 35 Sec. 1,3 | | Approvals, Canadian Standards Association | CSA Certified; File no. LR95329-1 | | Comments | With LED for lockout indication, and manual trip lever on safety switch to assure burner shutdown during servicing. | | Tradeline Value | Tradeline | |
|