Home > Zone Valves
SEARCH:  
Advanced Search 

HONE176: Honeywell V8043E1020 24V Motorized Zone Valve
Enlarge
Honeywell V8043E1020 24V Motorized Zone Valve

Price: $121.49
Now $72.13
Quantity:

 

ON-OFF and two-way low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water.

  • Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored.
  • All models may be installed without disassembling the valve.
  • Compact construction for easy installation.
  • Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system.
  • Actuator motor may be replaced without removing the valve body or draining the system.
Description 24V 1 in. Sweat Connection Low Voltage Motorized Zone Valves
Application Hydronic Control
Connection Type Sweat
Pipe Size (inch) 1 in.
Pipe Size (DN) DN25
Body Pattern Two-way, Straight-through
Capacity (Cv) 3.5 Cv
Capacity (Kv) 3 Kv
De-energized Position Normally Closed
Maximum Close-off Pressure (psi) 20 psi
Maximum Close-off Pressure (kPa) 138 kPa
Fluid Temperature Range (F) 50 F to 200 F
Fluid Temperature Range (C) 10 C to 93 C
Electrical Connections (in.) 18 in. leads
Electrical Connections (mm) 457 mm leads
Power Consumption 7.7 VA
Nominal Timing (sec, min) 15 sec
Valve Action Spring return to close
Maximum Ambient Temperature (F) 125 F
Maximum Ambient Temperature (C) 52 C
Dimensions (in.) 4 in. high x 3 11/16 in. wide x 2 3/8 in. deep
Dimensions (mm) 102 mm high x 94 mm wide x 60 mm deep
Type 2 position
End Switch SPST
End Switch Rating 50 VA pilot duty @ 24 V
End Switch Rating 4.4 A running with 26.4 A inrush @ 120 V
Static Pressure (psi) 125 psi
Static Pressure (kPa) 862 kPa
Materials (Body) Brass
Materials (Seat) Brass
Materials (Stem) Stainless Steel
Materials (Ball Plug) Buna-N (NBR) Rubber Ball
Materials (Packing O-rings) EPDM rubber
Voltage 24 Vac
Frequency 60 Hz
Frequency 50 Hz
Approvals, Underwriters Laboratories Inc UL Component Listed: File MH11826 Vol. 1
Manual Opener Yes
Comments Valve designed for cycling (not constantly powered on) applications.
Comments Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water.
Tradeline Value Tradeline

 